Product Center
Heating equipment series tailored for research scenarios
KHL-V1000 Laser Body Heating System

Product Overview
The KHL-V1000 Laser Body Heating System is a non-contact precision heating solution designed for high-temperature materials research and industrial heat treatment applications. Using high-power laser as the heat source, the system employs optical beam shaping, focusing, and energy control to deliver precise energy to target areas, enabling rapid heating, localized treatment, and highly responsive temperature control. Integrated components include the laser source, optical transmission module, heating chamber, infrared temperature measurement module, control system, and safety structures. The system can be customized based on material type, dimensions, and process requirements, making it ideal for high-temperature performance testing, heat treatment development, scientific experimentation, and automated production integration. Leveraging the laser's high directionality and energy density, the system achieves rapid surface energy input through beam shaping and focusing. Combined with infrared temperature feedback and closed-loop control algorithms, it dynamically adjusts laser output power in real-time to maintain stable heating, hold constant temperatures, and execute complex thermal profiles.
Product Positioning
Laser Non-Contact Volumetric Heating
High-power laser, after optical shaping and focusing, precisely targets the area to achieve rapid heating, localized thermal treatment, and high-response temperature control.
High-Temperature Research and Heat Treatment Platform
Integrates laser source, heated chamber, infrared temperature measurement, and closed-loop control for high-temperature material testing, process development, and automated integration.
Product Type
How it works
The system leverages the laser's high directionality and energy density, using beam shaping and focusing to rapidly deliver energy to the sample surface. Absorbed laser energy converts to heat, quickly raising the temperature of the target area. Integrated with infrared thermometry feedback and a closed-loop control algorithm, the system dynamically adjusts laser output power based on real-time temperature changes to achieve stable heating, precise temperature holding, and complex temperature profile control.
The system integrates a laser source, optical transmission module, heating chamber, infrared temperature measurement module, control system, and safety protection structure. Non-contact heating eliminates contamination, mechanical interference, and thermal inertia associated with traditional contact heating. It is customizable for different materials, sizes, and process requirements, making it suitable for high-temperature material testing, heat treatment process development, research experiments, and integration into automated production lines.
Important Notice:The maximum temperature (1200~1800°C), temperature control accuracy (±1~±5°C), and maximum heating rate (100°C/s) depend on material absorptivity, sample size, measurement method, and operating conditions. For official projects, the agreed test conditions and acceptance criteria shall prevail.
Core Advantages
A non-contact body heating system built with a 1000 W high-power laser, featuring optical beam shaping and focusing for high energy density and rapid response. Precise temperature profile control is achieved via infrared closed-loop feedback.
High-energy-density heating
Laser focusing creates a high-power-density heat source for rapid heating.
Contactless heating
Avoid contamination, mechanical interference, and thermal inertia caused by traditional contact heating methods.
Precise Temperature Control
Integrate infrared temperature feedback for dynamic power adjustment and closed-loop temperature control.
Rapid Response Capability
Suitable for thermal shock, thermal cycling, and transient temperature change testing.
Modular design
The laser source, optical system, heating chamber, and control system can be flexibly configured.
Secure and Reliable
Features laser safety protection, interlock protection, and anomaly alerts.
Highly customizable
Custom development available based on sample size, temperature requirements, and test platform.
Key Technical Specifications
| Device Model | KHL-V1000 |
| Heating Method | Laser non-contact heating |
| Laser Power | 1000 W |
| Laser wavelength | 808 nm / 915 nm / 980 nm (configurable based on requirements) |
| Maximum temperature | 1200℃~1800℃ (varies with material absorptivity and operating conditions) |
| Temperature Control Accuracy | ±1℃ to ±5℃ (determined by measurement method and operating conditions) |
| Heating rate | Up to 100°C/s (varies by sample size and material) |
| Heating Zone | Supports spot, localized, and custom heating |
| Temperature Measurement Method | Infrared Thermometer / Pyrometer / Thermocouple Combo |
| Control Mode | PLC Control / IPC Control / Software Closed-Loop Control |
| Cooling Method | liquid cooling |
| Power Requirements | AC 380 V / 50 Hz |
| Custom Services | Customizable structural, optical, control, and process parameters |
Typical Applications
High-Temperature Performance Testing for Aerospace Materials
Research on Superalloys, Ceramic Matrix Composites, and Thermal Barrier Coatings
Simulation and Process Study of Heat Sources in Additive Manufacturing
Localized heating for semiconductors, electronic packaging, and precision components
Material Thermal Cycling, Thermal Shock, and Thermal Fatigue Testing
High-Temperature Experimental Platform Construction for Research Institutes
Rapid Heat Treatment and Process Validation for Industrial Materials
System Configuration and Control Mode
| Configuration Type | Typical Components | Use Cases |
|---|---|---|
| Basic Power Regulation | Focusing heating head, power controller, cooling assembly, mounting bracket | Process exploration, rapid heating, and experiments with low constant-temperature precision requirements. |
| Closed-loop temperature control | Basic Configuration + Thermocouple or Infrared Temperature Sensor + PID Controller | Target temperature control, heat preservation, over-temperature protection, and repeatability testing |
| Automated Integration Suite | Closed-loop system + 3-axis platform/robotic arm + data acquisition and host computer | Multi-point switching, scan heating, test process linkage, and automatic recording |
Selection Details & Customization Services
Product power, focal length, and control method should be determined jointly based on the sample and test objectives. Before selection, clarify the following information to ensure the spot size, heating rate, and temperature stability meet actual operating conditions:
- Sample material, dimensions, thickness, weight, and surface condition
- Heated zone dimensions, target temperature, allowable ramp-up time, and hold time
- Temperature fluctuation, repeatability, measurement accuracy, and whether temperature curve logging is required
- Fixed-point scanning, multi-position switching, or mobile scanning
- Installation space, working distance, fixture interference, and cooling and safety protection conditions
Available Customizations
- Different power outputs, focal lengths, and target spot sizes
- Fixed, adjustable-angle, or three-axis movable mounting structures
- Thermocouple, Infrared Thermometry, and Dual-Point Verification Solution
- PID closed-loop temperature control, programmable temperature ramping, hold function, and over-temperature protection
- Temperature, Power, and Alarm Data Collection and Export
- Integrate with test machines, robotic arms, fixtures, and automation platforms
Usage and Safety Instructions
- ⚠Strong visible and infrared radiation is emitted during operation. Do not look directly at the light source or focus area. Use appropriate eye and radiation protection equipment.
- ⚠The sample, heating head tip, and surrounding structures may be hot. Install heat guards and allow adequate cooldown time after power-off.
- ⚠Keep the air-cooled channel clear. Do not operate continuously if cooling is abnormal, the reflector surface is contaminated, or electrical connections are loose.
- ⚠Infrared temperature readings are affected by emissivity, angle, and spot size coverage. For highly reflective metals, combine with thermocouples or use a calibrated measurement solution.
- ⚠For adhesives, coatings, and materials that may emit volatiles, evaluate ventilation, smoke extraction, and fire safety conditions.
Product Value
High-power laser heating via optical shaping and focusing enables non-contact volumetric heating. Integrated with infrared temperature measurement for closed-loop control, it is ideal for high-temperature material testing, heat treatment process development, research experiments, and automated production integration.